Hospitals

IS THE DISTRIBUTION SYSTEM AT YOUR HOSPITAL EXPERIENCING THESE PROBLEMS?

[icon_box style=”1″ icon=”fa-adjust” image=”https://thermalsciencetech.com/wp-content/uploads/2015/12/steam_manhole_vapor_tst1-1.png” title=”UNSIGHTLY STEAM VAPOR”]
[/icon_box][icon_box style=”1″ icon=”fa-adjust” image=”https://thermalsciencetech.com/wp-content/uploads/2015/12/heat_damaged_streets_tst1.png” title=”HEAT-DAMAGED STREETS, SIDEWALKS & UTILITIES”]
[/icon_box]
[icon_box style=”1″ icon=”fa-adjust” image=”https://thermalsciencetech.com/wp-content/uploads/2015/12/increased_fuel_costs_tst1.png” title=”INCREASED FUEL COSTS AT PLANT”]
[/icon_box][icon_box style=”1″ icon=”fa-adjust” image=”https://thermalsciencetech.com/wp-content/uploads/2015/12/steam_line_losses_tst1.png” title=”LINE LOSSES”]
[/icon_box]
[icon_box style=”1″ icon=”fa-adjust” image=”https://thermalsciencetech.com/wp-content/uploads/2015/12/missing_manhole_insulation_tst1.png” title=”MISSING INSULATION IN MANHOLES/VAULTS”]
[/icon_box][icon_box style=”1″ icon=”fa-adjust” image=”https://thermalsciencetech.com/wp-content/uploads/2015/12/degraded_mechanical_pipe_insulation_tst1.png” title=”MISSING INSULATION IN MECHANICAL ROOMS OR PLANTS”]
[/icon_box]

IF SO, HERE’S WHERE TST CAN HELP

[history_list align=”right” animate=”fadeInLeft”][history_item icon=”fa-cog” title=”BURIED DISTRIBUTION PIPING”]Repair and upgrade insulation within aged underground steam and hot water distribution piping with a trenchless technology.
[/history_item][history_item icon=”fa-cog” title=”MANHOLE PIPING”]Capture energy losses in manholes, vaults and pits by installing custom-made insulation blankets on bare pipe and fittings.
[/history_item][history_item icon=”fa-cog” title=”BOILER PLANTS”]Recover energy losses by installing removable insulation blankets and/or conventional pipe insulation on pipe, fittings and equipment.
[/history_item][/history_list]
[history_list align=”left” animate=”fadeInRight”][history_item icon=”fa-cog” title=”MECHANICAL ROOMS”]Reduce energy losses by installing removable insulation blankets and/or conventional pipe insulation on pipe, fittings and equipment.
[/history_item][history_item icon=”fa-cog” title=”UNDERGROUND TUNNELS”]Cut energy losses by installing removable insulation blankets and conventional pipe insulation on out-of-sight pipe and fittings.
[/history_item][history_item icon=”fa-cog” title=”CRAWLSPACES”]Recover energy losses by installing custom-made insulation blankets and conventional pipe insulation on out-of-sight pipe and fittings.
[/history_item][/history_list]

HERE’S HOW TST CAN HELP

buried_steam_pipe_repair_tst

ConduFill®

Restore the efficiency of thermally-degraded buried distribution piping and reduce heat loss by 40-90%.

Average payback: 2 – 5 years

removable_insulation_covers_tst

Removable Insulation Covers

Custom-made insulation covers restore the efficiency of bare pipe, fittings and equipment while protecting personnel.

Average payback: 6 – 18 months

mechanical_pipe_insulation_tst1

Mechanical Pipe Insulation

Turnkey removal, repair and installation of mechanical insulation for bare piping in manholes, mechanical rooms, tunnels, and vaults.

Average payback: 1 – 3 years

WOULD THE SYSTEM AT YOUR HOSPITAL BENEFIT FROM AN INSULATION ASSESSMENT?

 

Find out today by telling us more about your system below.

    Your Name (required)

    Your Email (required)

    How many linear feet (or miles) of buried steam or hot water distribution piping do you have at your facility?

    What is the typical range of pipe sizes for the underground distribution lines?

    What is the typical pressure/temperature for the distribution lines?

    What is the production cost for steam?

    The construction of your distribution piping system consists mainly of:

    Are there any signs of excessive heat loss on the surfaces above the existing steam or hot water distribution lines?

    If yes, which signs?

    Approximately how many manholes/pits/vaults can be found on the distribution loop at your facility?

    How would you describe the existing insulation on the piping within manholes or pits or vaults?

    Are manholes/pits/vaults frequently flooded causing live piping to be submerged?

    Are any manholes/pits/vaults too hot to enter for routine maintenance and/or inspections? If so, how many?

    Other Comments

    Enter your keyword